Pengaruh Variasi Beban Produk Terhadap Kerja Kompresor Pada Sistem Ice Maker Berbasis Brine Cooling

Penulis

  • Marvelyano Petra Sampara Universitas Pattimura Ambon Penulis
  • Cendy Sophia Edwina Tupamahu Universitas Pattimura Ambon Penulis
  • Sefnath Josep Etwan Sarwuna Universitas Pattimura Ambon Penulis

DOI:

https://doi.org/10.65310/1y3dt168

Kata Kunci:

Product Load, Brine Cooling, Power Consumption, Compressor Work, Refrigeration System.

Abstrak

Refrigeration systems play a crucial role in cooling and freezing processes within low-temperature-based industries. In brine cooling-based ice maker systems, performance is highly dependent on the compressor as the primary component in the vapor compression cycle. Variations in product load lead to changes in heat load, which directly affect compressor work and energy consumption. This study aims to analyze the effect of product load variations on compressor work and electrical power consumption. An experimental method was employed with load variations of 25, 30, and 35 water packages (0.8 kg per package). The observed parameters included pressure, temperature, compressor work, and power consumption. Data were collected through direct measurements using K-type thermocouples, manifold gauges, and watt meters, and subsequently analyzed based on vapor compression cycle equations. The results indicate that increasing the product load raises compressor work from 72.54 kJ/kg to 73.47 kJ/kg and power consumption from 5797.8 Watts to 6842.86 Watts. Additionally, higher loads result in increased discharge pressure, compressor outlet temperature, and longer freezing time. It can be concluded that product load significantly affects system performance and energy consumption.

Unduhan

Data unduhan tidak tersedia.

Referensi

Alfanda, B. D., Kusuma, G. E., Maulana, Z., & Muninggar, R. (2025). Experimental Optimization of R-134a Refrigerant Charge in a Retrofitted Dual Function Refrigeration System for Marine Engineering Applications. International Journal of Marine Engineering Innovation and Research, 10(4), 1399-1407. https://doi.org/10.12962/j25481479.v10i4

Anwar, K. (2010). Efek beban pendingin terhadap performa sistem mesin pendingin. Smartek, 8(3), 221671.

Darmawan, D. B. (2023). Analisa Performance Mesin Ice Maker Menggunakan Outdoor Ac Berkapasitas 7 Kg. Jurnal Rekayasa Energi, 2(2), 31-35. https://doi.org/10.31884/jre.v2i2.37

Huda, A. A., Karyanik, K., & Dewi, E. S. (2021). Efek variasi beban pendinginan terhadap Coefficient of performance (COP) mesin pendingin pada box cooler alat distilasi. Jurnal Agrotek Ummat, 8(2), 110–115.

Indartono, Y. S., & Mustikaningtyas, A. (2022, September). Solar Powered Ice Maker System in Karimunjawa Island, Indonesia. In MMBD (pp. 352-360).

Kusnandar, K., & Kurniawan, Y. (2020). Perbandingan Cop AC Split Kapasitas 1 Pk Menggunakan Refrigerant R410a Dan R32 Dengan Variasi Kecepatan Fan Evaporator. TURBULEN Jurnal Teknik Mesin, 2(2), 50-55. https://doi.org/10.36767/turbulen.v2i2.553

Lubis, S., Siregar, M. A., & Damanik, W. S. (2022). Uji Eksperimental Kemampuan Lemari Pembeku Terhadap Beban Pendingin Menggunakan Energi Matahari. Media Mesin: Majalah Teknik Mesin, 23(1), 52-58. https://doi.org/10.23917/mesin.v23i1.15717

Mainil, A. K. (2012). Kaji eksperimental performansi mesin pendingin kompresi uap menggunakan refrigeran hidrokarbon (HCR12) sebagai alternatif pengganti R12 dengan sistem drop-in substitute. MECHANICAL, 3(1). https://doi.org/10.23960/mech.v3i1.142

Mastur, M., Setiyawan, K., & Sugiantoro, B. (2016). Pengaruh variasi beban, waktu pendinginan dan temperatur ruang terhadap performasi mesin pendingin. Techno, 17(1), 43–47. https://doi.org/10.30595/techno.v17i1.78

Mitrakusuma, W. H., Setyawan, A., & Putri, R. D. R. (2018). Pengaruh Variasi Debit Refrigeran Sekunder Terhadap Kinerja Sistem Chiller Brine Cooling. Pros Nas Rekayasa Teknol Ind dan Inf, 13, 2018.

Muharni, R., Suryadimal, S., Afrianda, A., Kaidir, K., Martiana, W., & Kesuma, D. S. (2023). Analisis Performa Sistem Pendingin Mesin Mini Water Chiller. Jurnal Teknik Mesin, 16(1), 30-36. https://doi.org/10.30630/jtm.16.1.1063

Pamungkas, K. P., Mitrakusuma, W. H., & Lukitobudi, A. R. (2023, August). Rancang Bangun Miniatur Arena Ice Skating Dengan Sistem Brine Cooling. In Prosiding Industrial Research Workshop and National Seminar (Vol. 14, No. 1, pp. 580-585). https://doi.org/10.35313/irwns.v14i1.5451

Penangsang, O., Aisjah, A. S., Arifin, S., Indriawati, K., Wahyuono, R. A., Widjiantoro, B. L., ... & Asyari, M. K. (2022). Bawean Innovative Ice Maker For Economist Fish Cooling System (BIM-Fish). Sewagati, 6(1), 85-91. https://doi.org/10.12962/j26139960.v6i1.176

Purwanto, E., & Ridhuan, K. (2014). Pengaruh Jenis Refrigerant Dan Beban Pendinginan Terhadap Kemampuan Kerja Mesin Pendingin. Turbo: Jurnal Program Studi Teknik Mesin, 3(1). http://doi.org/10.24127/trb.v3i1.19

Ramdhani, M. R., Muliawan, R., & Khakim, N. (2023, August). Analisis Pengaruh Variasi Kecepatan Fan Kondenser Terhadap Performansi Sistem Brine Cooling Untuk Pembuatan Es Balok. In Prosiding Industrial Research Workshop and National Seminar (Vol. 14, No. 1, pp. 147-153). https://doi.org/10.35313/irwns.v14i1.5376

Rizkyana, Q., Pramudantoro, T. P., & Muliawan, R. (2023, August). Rancang Bangun Sistem Brine Cooling yang Dilengkapi Liquid Suction Heat Exchanger untuk Pembuatan Es Balok. In Prosiding Industrial Research Workshop and National Seminar (Vol. 14, No. 1, pp. 291-296). https://doi.org/10.35313/irwns.v14i1.5401

Samsi, S., Hermawan, A., Binardi, T., Ilham, M., & Rahardja, I. B. (2023). Analisa beban pendingin produk pada contact plate freezer terhadap kinerja kompresor di PT. Trimitra Makmur, Tarakan, Kalimantan Utara. Jurnal Teknologi, 15(2), 207-216. https://doi.org/10.24853/jurtek.15.2.207-216

Santosa, A., Setiawan, A., Anwar, Saepudin, A., Kusnadi, Darussalam, R., ... & Purwanto, A. J. (2024, August). Design and construction of compressor heat recovery utilization of ice machine for drying system. In AIP Conference Proceedings (Vol. 3069, No. 1, p. 020116). AIP Publishing LLC. https://doi.org/10.1063/5.0206057

Setiawan, A., & Imam, M. (2023). Analisis pengaruh variasi putaran extra fan evaporator terhadap kinerja cold storage menggunakan mesin outdoor AC split untuk penyimpanan puree mangga. JURNAL REKAYASA ENERGI, 2(2), 1-10. https://doi.org/10.31884/jre.v2i2.41

Sormin, I. A., Gunadnya, I. B. P., & Aviantara, I. G. N. A. (2023). Kinerja kotak pendingin (cooler box) berpendingin TEC1-12715 pada beberapa beban pendinginan. Jurnal Beta (Biosistem dan Teknik Pertanian), 11(1), 29–37. https://doi.org/10.24843/JBETA.2023.v11.i01.p04%20

Sunardi, C., Sutandi, T., Putra, A. D. D., & Kosasih, A. (2019). Pengaruh refrigeran R-22 dan MC-22 terhadap performansi sistem refrigerasi brine Cooling. Edusaintek, 3.

Junaedy, I., Temaja, I. W., & Subagia, I. (2022). Pengaruh Beban Terhadap Performansi Pada Multiple Compressor Rack Refrigeration System Trainer Gt-500 (Doctoral dissertation, Politeknik Negeri Bali).

Tupamahu, C., Tentua, B. G., Hulihulis, T., & Nurhaeny, A. (2024). Variasi Lilitan Pipa Kapiler Terhadap Kerja Unit Pembuat Es Menggunakan Outdoor AC 1 PK. Teknobiz: Jurnal Ilmiah Program Studi Magister Teknik Mesin, 14(3), 202-206. https://doi.org/10.35814/teknobiz.v14i3.7847

Zhu, Z., Liang, K., Chen, H., & Meng, Z. (2022). Inherent capacity modulation of a linear refrigeration compressor. International Journal of Refrigeration, 143, 182-191. https://doi.org/10.1016/j.ijrefrig.2022.06.032

Unduhan

Diterbitkan

2026-04-29

Cara Mengutip

Pengaruh Variasi Beban Produk Terhadap Kerja Kompresor Pada Sistem Ice Maker Berbasis Brine Cooling. (2026). Journal of Engineering and Applied Technology, 2(1), 177-185. https://doi.org/10.65310/1y3dt168